Fit Check on every partFree shipping over $4930-day returns
Help: contact us
HVAC FitterTHE PART THAT FITS
PART NUMBER · YORK

York 32544123000 Gas Valve Assembly

Out of stock

The 32544123000 gas valve assembly is a gas heating control compatible with York equipment. It regulates the flow of fuel to your heating burners.

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy

When the heating cycle starts, this component opens to supply fuel for combustion. It shuts off fuel flow when the call for heat ends or if safety switches detect an issue.

Safety first. If you smell gas, do not touch any switch or phone inside. Leave the house right away and call your gas company from outside. Turn off electrical power at the breaker and test for power before touching any wires or controls. Gas valve work means opening gas lines and setting gas pressure. We strongly suggest a licensed tech does the install.

Specifications

FROM THE PART LISTINGS
  • Part number: 32544123000
  • Brand: York
  • Part type: Gas valve assembly
  • Diameter: 1/2"
  • Dimensions: 4.8 × 5.6 × 3.6 in
  • Ignition: Direct Spark or Hot Surface
  • Pressure: 3.5" W.C.
LISTED AS REPLACING
  • S1-02530789000
  • S1-02530888000
  • S1-02531969000
  • S1-02531996000
  • S1-02532643000
  • S1-02535317000
  • S1-02537426000
  • S1-02632643000
  • S1-2702-326P
  • S1-2702-331P
  • S1-32537426000
  • S1-36F24-206
MATCH THESE NUMBERS ON YOUR OLD GAS VALVE
  • Gas type: natural gas or propane, as listed
  • Ignition: same type as your furnace
  • Pipe size and BTU: same pipe size, rated for your furnace

From the maker's and parts sellers' listings for this number. Compare them with the label on your old part.

What the Gas Valve Assembly Does

A gas valve assembly controls fuel delivery to your furnace burners. Most control boards and thermostats send a 24 V control signal to operate the valve during a call for heat.

The valve holds gas back until ignition begins. Once the heating cycle finishes, the valve closes tightly to stop fuel flow.

If safety controls detect an issue, the valve remains closed. Never bypass a flame sensor, pressure switch, limit switch, or rollout switch to force the valve to open.

Understanding the Specs for 32544123000

Matching the physical size and pressure ratings of your valve is critical for safe heating operation.

  • Diameter: 1/2"
  • Dimensions: 4.8 × 5.6 × 3.6 in
  • Ignition: Direct Spark or Hot Surface
  • Pressure: 3.5" W.C.

Confirming a Replacement Matches

Check your old component carefully before seeking a replacement. You must confirm the gas type, such as natural gas or propane as listed for your setup.

The replacement must match the pipe size and BTU rating for your furnace. It must also match the ignition type of your heating unit.

This part number replaces several older numbers. It replaces S1-02530789000, S1-02530888000, S1-02531969000, S1-02531996000, S1-02532643000, S1-02535317000, S1-02537426000, S1-02632643000, S1-2702-326P, S1-2702-331P, S1-32537426000, and S1-36F24-206.

Signs of Failure and Safe Replacement Steps

A faulty valve may stop burners from lighting even when the igniter glows and safety switches close. Always check basic causes first. For example, if burners light and go out after 3 to 10 seconds, a dirty flame sensor is a common cause.

Before handling any wiring, take a photo of every wire. Move wires one at a time to the matching spots on the replacement control.

Never attempt to bypass safety devices to diagnose a bad valve. Always ensure the shutoff valve on the gas line is turned completely off before working.

Read your old part

  1. Locate the rating label on your existing gas valve assembly.
  2. Wipe away dust to read the model or part number clearly.
  3. Check if the label displays part number 32544123000.
  4. If not, check if your number matches a listed replacement number such as S1-02537426000 or S1-32537426000.
  5. Verify your furnace ignition uses Direct Spark or Hot Surface ignition.

When to call a pro

Gas valve work means opening gas lines and setting gas pressure. A licensed tech should do it. Hire a licensed HVAC technician for any step you are not sure you can do safely.

Questions

What control voltage operates this gas valve?

Most home thermostats, contactor coils, and control boards use a 24 V control signal from a transformer to operate components like this valve.

What ignition systems work with part 32544123000?

This valve is rated for systems using Direct Spark or Hot Surface ignition. Verify your furnace ignition type matches before installing a replacement.

What should I do if I smell gas around the furnace?

If you smell gas, do not touch any switch. Leave the house right away and call your gas company from outside.

Can I replace the gas valve myself?

Gas valve work means opening fuel lines and setting manifold pressure. Because of the safety risks, we strongly suggest a licensed pro completes the install.

Related part numbers

Browse: Furnace gas valves by part number

All part numbers · Part number replacements · Shop gas valves · Repair guides

Brand names and part numbers identify the part and show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.