This part is out of stock right now, so it cannot be added to the cart.
When the thermostat calls for heat, the furnace control sends a low voltage signal to open the valve. This releases gas to the burners, where it is lit by the ignition system.
Specifications
- Part number: 327972756
- Brand: Carrier
- Part type: Gas valve assembly
- Gas type: Natural Gas
- Pressure: 3.5" W.C.
- Voltage: 24V
- Wiring: 1/2″
- Gas type: natural gas or propane, as listed
- Ignition: same type as your furnace
- Pipe size and BTU: same pipe size, rated for your furnace
From the maker's and parts sellers' listings for this number. Compare them with the label on your old part.
How the Gas Valve Works
A gas valve acts as an automatic switch and pressure regulator for fuel. It stays closed until the furnace controls confirm that all safety checks are satisfied.
Once the system proves the draft is clear, the control board sends power to the valve coil. The internal valve opens, sending fuel through the burner manifold. If safety switches open or the flame is not detected, the valve immediately shuts off the gas supply.
Understanding the 327972756 Specs
Every gas valve has specific ratings stamped on its label. Matching these exact values is necessary for correct operation and home safety.
- Gas type: Natural Gas. This valve is set up for natural gas supply lines.
- Pressure: 3.5" W.C. This is the water column pressure rating for the gas output.
- Voltage: 24V. The valve operates using a standard 24-volt control signal.
- Wiring: 1/2″. This matches the designated wiring connection size on the unit.
Confirming a Correct Match
Do not guess when replacing a gas control. You must verify that the physical and mechanical traits match your heating system.
Check that the gas type matches, such as natural gas or propane, exactly as listed. The valve must also match the ignition type of your furnace. Finally, make sure the replacement has the same pipe size and is rated for the BTU output of your furnace.
Troubleshooting and Safe Replacement
If your furnace igniter glows or sparks, but the main burners never light, the gas valve may not be opening. However, other safety devices can cause this as well. A pressure switch, limit switch, or rollout switch will prevent the valve from getting power if an issue exists. Never bypass these switches.
Before handling any wiring, take a clear photo of the connections. When attaching wires, move them one at a time to the same spots on the replacement valve. Because opening gas pipes requires leak checks and proper manifold pressure adjustments, this task should be handled by a qualified technician.
Read your old part
- Turn off the electrical power and shut off the manual gas shutoff valve to the furnace.
- Locate the metal identification tag or printed label on the body of your current gas valve.
- Clean off any dust to clearly read the model or part number stamped on the casing.
- Check that the number shows 327972756.
- Confirm the fuel type on the label states Natural Gas and the pressure rating shows 3.5" W.C.
When to call a pro
Gas valve work means opening gas lines and setting gas pressure. A licensed tech should do it. If you are not sure you can complete any step safely, stop and hire a licensed HVAC technician.
Questions
What should I do if I smell gas around my furnace?
Leave the house immediately. Do not touch any electrical switches or use phones inside the home. Call your gas company from outside once you are safe.
Can I replace a natural gas valve with a propane valve?
No, you cannot swap them directly. The gas type must match your fuel supply, whether natural gas or propane, as listed on the part. Using the wrong fuel type creates severe safety hazards.
What voltage does the 327972756 gas valve use?
This valve uses a 24V control signal. Most home thermostats and furnace control boards provide this 24 V control signal from an internal transformer.
Can I bypass a safety switch to see if my gas valve works?
No, you must never bypass a safety switch. Flame sensors, pressure switches, limit switches, and rollout switches protect your equipment and home. Bypassing them can cause severe damage or fire.
Related part numbers
- EF32CW151Gas Valve, CarrierSame brand and type
- EF34CW246Gas Valve Reference, CarrierSame brand and type
- 32544123000Gas Valve Assembly, YorkSame part type
- 1172822Gas Valve Assembly, ArcoaireSame part type
- 17400101000020Capacitor, CarrierSame brand
- 33010025Air Conditioner Capacitor, CarrierSame brand
- 0151F00000PSGas Valve, GoodmanSame part type
- 15012466Condenser Fan Motor, CarrierSame brand
Browse: Carrier part numbers · Furnace gas valves by part number
All part numbers · Part number replacements · Shop gas valves · Repair guides
Brand names and part numbers identify the part and show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.