Fit Check on every partFree shipping over $4930-day returns
Help: contact us
HVAC FitterTHE PART THAT FITS
PART NUMBER · VULCAN HART

Vulcan Hart 00-420560-00001 Gas Valve

Out of stock

This reference page covers part number 00-420560-00001, a gas valve listed under the Vulcan Hart brand. A gas valve manages fuel flow to the burners, making sure the equipment gets fuel only when needed.

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy

If you are holding an old part with this number, checking the markings and physical dimensions helps you find the correct replacement. Fuel lines require exact fits to work safely.

Safety first. If you smell gas, leave the house immediately. Do not touch any switches or phones inside. Call your gas company from outside. Turn off the electrical power at the breaker and test for power before touching any wiring. Gas valve work means opening gas lines and setting gas pressure. We strongly suggest a licensed tech does the install.

Specifications

FROM THE PART LISTINGS
  • Part number: 00-420560-00001
  • Brand: Vulcan Hart
  • Part type: Gas valve
  • Height: 1.4 in / 3.56 cm
  • Length: 2 in / 5.08 cm
  • Width: 2.1 in / 5.33 cm
MATCH THESE NUMBERS ON YOUR OLD GAS VALVE
  • Gas type: natural gas or propane, as listed
  • Ignition: same type as your furnace
  • Pipe size and BTU: same pipe size, rated for your furnace

From the maker's and parts sellers' listings for this number. Compare them with the label on your old part.

What the Gas Valve Does

A gas valve controls the flow of fuel inside your heating appliance. When the system calls for heat, the valve opens to send gas to the burners so they can ignite.

When the call for heat ends or if a safety switch detects a problem, the gas valve shuts tightly. This stops the flow of gas and keeps the appliance running safely.

Understanding the Part Dimensions

Replacing a gas component requires checking its physical size. Space inside the cabinet can be tight, so the replacement must fit the existing layout.

Part number 00-420560-00001 has the following recorded dimensions:

  • Height: 1.4 in / 3.56 cm
  • Length: 2 in / 5.08 cm
  • Width: 2.1 in / 5.33 cm

How to Confirm a Replacement Matches

Always match the exact part number from your old valve label before choosing a new part. Never rely on visual appearance alone.

When reviewing options for a replacement gas valve, check these essential matching points:

  • Gas type: natural gas or propane, as listed
  • Ignition: same type as your furnace
  • Pipe size and BTU: same pipe size, rated for your furnace

Signs of Valve Failure and Safe Replacement

A valve that fails to open will prevent your burners from lighting even if the igniter or pilot is working. A valve that sticks or fails to seal properly can cause fuel odors or safety shutdowns.

Working on fuel piping carries fire and explosion risks. Take a photo of every wire before removing any connections, and move wires one at a time to the same spots on the new part. Because gas lines must be disconnected and gas pressure must be set correctly, hire a licensed professional for the installation.

Read your old part

  1. Turn off electrical power and shut off the main gas supply to the unit.
  2. Locate the label or stamped markings on your existing valve body.
  3. Read the part number printed on the label and verify it shows 00-420560-00001.
  4. Measure the height, length, and width of your old component to verify they match the specs.
  5. Check that your fuel type, pipe size, and ignition type match the requirements of your heating unit.

When to call a pro

Gas valve work means opening gas lines and setting gas pressure. If you do not have the proper tools to test for leaks and verify manifold pressure, stop right away. Hire a licensed HVAC technician for any step you are not sure you can do safely.

Questions

What should I do if I smell gas around the unit?

Leave the house immediately. Do not touch any electrical switch or use phones inside the building. Call your gas company from outside once you are safe.

Can I replace a gas valve myself?

Gas valve work involves opening fuel lines and setting gas pressure. Because of the safety risks involved, a licensed technician should perform the installation.

What properties must match when replacing a gas valve?

You must confirm the gas type, such as natural gas or propane, as listed. You must also match the ignition type, the pipe size, and the BTU rating of your furnace.

What are the dimensions of part 00-420560-00001?

This part measures 1.4 in / 3.56 cm in height, 2 in / 5.08 cm in length, and 2.1 in / 5.33 cm in width.

Related part numbers

  • 36C03-400Gas Valve, White-RodgersSame part type
  • EF34CW246Gas Valve Reference, CarrierSame part type
  • 00-424194-00001Ignitor/Flame Sensor Assembly, Vulcan HartSame brand
  • 36C03-433Gas Valve Assembly Reference, White-RodgersSame part type
  • EF32CW151Gas Valve, CarrierSame part type
  • 36H64-463Gas Valve Assembly, CopelandSame part type
  • 32544123000Gas Valve Assembly, YorkSame part type

Browse: Furnace gas valves by part number

All part numbers · Part number replacements · Shop gas valves · Repair guides

Brand names and part numbers identify the part and show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.