Check the specs and the label on your old part.
2 Pole Contactor, Type 122, 24 VAC Coil, 30 Amp Contacts, 11 Ohms DC Resistance, 250 mA (White Rodgers 90-244)
This part is out of stock right now, so it cannot be added to the cart.
- 30-day returns on unused parts.
- 1-year warranty. Details
- Questions? Ask us to check the fit
Hold your old contactor next to this list. 3 ticks means it fits.
Specs
| Poles | 2 |
|---|---|
| Use | Heating |
| Temperature range | -40°F to 150°F |
| Mount | Plate |
| Hertz | 60 |
| Coil resistance | 11 ohms |
| Coil current (mA) | 250 |
| Wiring | 1/4" Quick-Connect Terminals |
| Duty | Continuous |
| Amps (FLA) | 30 A |
| Coil inrush (VA) | 32 |
| Rating, full load | 30 A @ 600 Vac |
| Rating, locked rotor | 150 A @ 277 Vac |
| Continuous rating | 40 |
| Coil voltage | 24V |
| Condition | New |
Will it fit?
Match the specs on your old part. Brand does not matter. The numbers do.
Brand names and part numbers are shown only to help you find a compatible part. This is not a brand-made part. We are not affiliated with or endorsed by these companies.
Safety: read before you start
- Turn off power at the breaker. Then pull the disconnect by the outdoor unit.
- A capacitor can hold a charge after power is off. Do not touch its terminals until it is discharged.
- Take a photo of the wires before you remove them.
- Not comfortable with any step? Call a licensed HVAC tech.
What are the specs of 90-244?
Poles: 2; Use: Heating; Temperature range: -40°F to 150°F; Mount: Plate; Hertz: 60; Coil resistance: 11 ohms. Match these numbers with the label on your old contactor.
Shipping
Free standard shipping on orders over $49, to US addresses. You get tracking by email. Shipping policy.
Returns
Return unused parts within 30 days. Parts that were installed or wired in can not be returned unless they are defective. Return policy.
Warranty
1-year warranty against defects. Keep your order email. Warranty details.