Fit Check on every partFree shipping over $4930-day returns
Help: contact us
HVAC FitterTHE PART THAT FITS
PART NUMBER · WHITE-RODGERS

White-Rodgers 36C03-433 Gas Valve Assembly Reference

Out of stock

The White-Rodgers 36C03-433 is a gas valve assembly used on residential heating equipment. It controls the flow of fuel to the pilot and the main burners based on calls for heat from the system.

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy

When the thermostat calls for heat, electrical current opens the internal valve. This allows fuel to reach the burner assembly so combustion can warm your home.

Safety first. If you smell gas, do not touch any switch. Leave the house and call your gas company from outside. Gas valve work means opening gas lines and setting gas pressure. A licensed tech should do it. Turn off electrical power at the breaker before inspecting or touching any furnace wiring.

Specifications

FROM THE PART LISTINGS
  • Part number: 36C03-433
  • Brand: White-Rodgers
  • Part type: Gas valve assembly
  • Amps: 0.23A
  • Frequency: 60Hz
  • Gas type: LP, Natural Gas
  • Ignition: Standing Pilot
  • Voltage: 24 Vac 60Hz
MATCH THESE NUMBERS ON YOUR OLD GAS VALVE
  • Gas type: natural gas or propane, as listed
  • Ignition: same type as your furnace
  • Pipe size and BTU: same pipe size, rated for your furnace

From the maker's and parts sellers' listings for this number. Compare them with the label on your old part.

What the Gas Valve Assembly Does

A gas valve acts as the primary gatekeeper for fuel inside your heating system. It stays closed when there is no call for heat, preventing unburned gas from escaping.

Once the pilot flame is established and the controls verify conditions are correct, the valve opens to send fuel to the main burners. It closes immediately once the heating cycle ends or if a safety control interrupts the circuit.

Understanding the 36C03-433 Specifications

Every gas valve is built to handle specific electrical inputs and fuel types. Always compare your old unit label directly against these values.

  • Voltage: 24 Vac 60Hz
  • Amps: 0.23A
  • Frequency: 60Hz
  • Gas type: LP, Natural Gas
  • Ignition: Standing Pilot

How to Confirm a Replacement Matches

Matching a replacement requires checking both physical and electrical characteristics against the existing equipment.

Use these general match points to verify fit before proceeding with any repair:

  • Gas type: natural gas or propane, as listed on the rating plate
  • Ignition: same type as your furnace, which must support a Standing Pilot system
  • Pipe size and BTU: same pipe size, rated for your furnace
  • Check the replaces list: find the part number on your old valve to confirm compatibility

Signs of Valve Failure and Safe Replacement Steps

When a gas valve fails, the burners may refuse to light even when the pilot stays burning and the thermostat calls for heat. In other cases, an internal coil failure prevents the main port from opening.

Take a photo of every wire before removing a part. Move wires one at a time to the same spots on the new part. Because the installation requires breaking gas pipe connections and verifying line pressure, have a professional handle the physical swap.

Read your old part

  1. Turn off electrical power to the furnace at the circuit breaker.
  2. Remove the access panel to locate the installed gas valve assembly.
  3. Wipe dust from the metal specification label on the valve body.
  4. Locate the printed model or part number on the label.
  5. Confirm the label clearly reads 36C03-433.

When to call a pro

Call a licensed pro: Gas valve work means opening gas lines and setting gas pressure. We strongly suggest a licensed tech does the install. Hire a licensed HVAC technician for any step you are not sure you can do safely.

Questions

What ignition type does the 36C03-433 use?

This valve is designed for a Standing Pilot ignition system. It is not compatible with direct spark or hot surface ignition setups.

What fuel types can this valve handle?

The specifications list LP, Natural Gas for this part. The system setup and rating plate must match the specific fuel delivered to the home.

What electrical power does this gas valve require?

It operates on a control circuit rated at 24 Vac 60Hz. It has an electrical draw rated at 0.23A and runs at a frequency of 60Hz.

What should I do if I smell gas near the furnace?

If you smell gas, do not touch any switch or phone inside the house. Leave the home immediately and call your gas company from outside.

Related part numbers

Browse: Furnace gas valves by part number

All part numbers · Part number replacements · Shop gas valves · Repair guides