When your equipment calls for operation, a control signal energizes the internal coil. This magnetic pull closes the switch contacts so line power can flow to the connected parts.
Specifications
- Part number: 00-562597-00001
- Brand: Hobart
- Part type: Contactor
- Height: 2.85 in / 7.24 cm
- Length: 4.15 in / 10.54 cm
- Poles: 4 Pole
- Voltage: 120 Volt
- Width: 3.3 in / 8.38 cm
- Poles: same count, 1 or 2
- Coil volts: must be the same, most homes use 24 V
- Amps: same or higher than your old one
From the maker's and parts sellers' listings for this number. Compare them with the label on your old part.
What this contactor does
A contactor operates like an automatic relay for heavy electrical loads. Instead of running full line voltage through a delicate control board or thermostat, the equipment uses a lower-power control circuit.
This control circuit feeds the contactor coil. When energized, the coil creates a magnetic field that pulls the contacts closed. Power then flows through the poles to run the equipment. Once the call ends, the coil releases and opens the circuit.
Understanding the specifications
Every contactor must match its electrical and physical requirements exactly. Using incorrect ratings can damage equipment or cause electrical hazards.
- Voltage: 120 Volt coil rating. The control circuit must supply this exact coil voltage to pull the switch closed.
- Poles: 4 Pole configuration. This provides four separate sets of switch contacts to open and close multiple circuits at the same time.
- Height: 2.85 in / 7.24 cm.
- Length: 4.15 in / 10.54 cm.
- Width: 3.3 in / 8.38 cm.
Confirming a replacement match
When you hold an old contactor, check its printed data plate before choosing a new part. Coil voltage must match your old part exactly.
Poles must match the count of circuits your unit switches. The physical dimensions also matter so the replacement fits inside the control box and aligns with existing mounting holes.
Signs of wear and safe replacement
Over time, the repeated opening and closing of electrical contacts can cause pitting or burning. A failing contactor may make a loud buzzing noise, or the contacts might stick closed, keeping the equipment running continuously.
If the coil burns out or the contacts become too scorched, the switch will fail to close, and the unit will not turn on at all.
- Turn off power at the breaker panel and disconnect switch, then test all lines with a meter to verify power is dead.
- Take a clear photo of all existing wires connected to the old contactor terminals.
- Label each wire to track line, load, and coil connections.
- Unscrew the old contactor from its mounting plate.
- Mount the replacement part securely in the cabinet.
- Move wires one at a time to the matching terminals on the replacement contactor.
- Restore power and test the equipment through a normal operating cycle.
Read your old part
- Turn off all power to the equipment and verify with a voltage meter.
- Locate the label or stamp on the body of your existing contactor.
- Look for part number 00-562597-00001 printed on the part casing.
- Check that the coil voltage rating on the label states 120 Volt.
- Verify the switch has 4 Pole connections to match your wiring setup.
When to call a pro
Hire a licensed HVAC technician or licensed electrician for any step you are not sure you can do safely. If you are uncertain about wire routing, testing for voltage, or line voltage connections, stop and call a professional.
Questions
What coil voltage does part 00-562597-00001 use?
This contactor has a 120 Volt coil. The control circuit must supply this specific voltage to pull the contacts closed.
How many poles does this contactor have?
Part 00-562597-00001 has 4 Pole construction. This allows it to switch four separate electrical paths at once.
What are the dimensions of this contactor?
It measures 4.15 in / 10.54 cm in length, 3.3 in / 8.38 cm in width, and 2.85 in / 7.24 cm in height. Make sure your mounting space accommodates these measurements.
What should I do before touching the wires on my old contactor?
Always shut off power at the breaker and any local disconnect switches. Test for power with a meter to ensure it is dead, and take a photo of the wiring before removing any leads.
Related part numbers
- 42-25103-01Contactor, PROTECHSame part type
- 34200332Mini Contactor, RancilioSame part type
- 00-748512Control Board, HobartSame brand
- 369178Contactor Reference, LincolnSame part type
- 9101002-07Contactor Reference, Ice-O-MaticSame part type
Browse: Contactors by part number
All part numbers · Part number replacements · Shop contactors · Repair guides
Brand names and part numbers identify the part and show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.