Fit Check on every partFree shipping over $4930-day returns
Help: contact us
HVAC FitterTHE PART THAT FITS
PART NUMBER · LENNOX

Lennox 24L8501 Control Board

Out of stock

The Lennox 24L8501 is a furnace control board. This circuit board manages operations in your heating system, sending signals to run the furnace cycles.

This part is out of stock right now, so it cannot be added to the cart.

One email when it is back in stock. Nothing else. Privacy policy

In your equipment, the board directs low-voltage controls and ignition steps. It coordinates with safety devices and components to keep the furnace running smoothly.

Safety first. Turn off power to the furnace at the breaker panel and test for power with a meter before touching any wires. If you smell gas at any time, do not touch any switch. Leave the house right away and call your gas company from outside. Never bypass any safety device, including a flame sensor, pressure switch, limit switch, or rollout switch.

Specifications

FROM THE PART LISTINGS
  • Part number: 24L8501
  • Brand: Lennox
  • Part type: Control board
  • Ignition: SureLight Integrated Ignition
  • Material: Plastic / Fiberboard
  • System: Gas Furnace
  • Voltage: 24 V
MATCH THESE NUMBERS ON YOUR OLD CONTROL BOARD
  • Part number: listed as a replacement for yours
  • Ignition type: same as your furnace
  • Wiring: photo every wire first

From the maker's and parts sellers' listings for this number. Compare them with the label on your old part.

What the Lennox 24L8501 control board does

The control board operates as the central hub for your gas furnace. Most home thermostats and control boards communicate using a 24 V control signal from a transformer.

During a call for heat, the board monitors safety switches, manages the ignition sequence, and controls the blower. It ensures each stage happens in order before opening the gas valve.

What the specifications mean

Reviewing the listed ratings helps you understand how this board operates inside your furnace equipment.

  • Voltage: 24 V. This is the low-voltage control signal powering the board circuits.
  • System: Gas Furnace. Designed for use in residential gas heating systems.
  • Ignition: SureLight Integrated Ignition. Matches systems built around this specific ignition setup.
  • Material: Plastic / Fiberboard. The structural materials used to build the printed circuit board base.

How to confirm a match

Circuit boards must match the heating system's design. Installing an incorrect board can cause sequence errors or prevent the furnace from running.

  • Part number: Make sure the replacement board is listed as a replacement for yours.
  • Ignition type: Ensure the ignition type matches your furnace, such as SureLight Integrated Ignition.
  • Wiring: The board must match the wiring layout of your furnace.

Safe replacement steps

Control boards have many wire connections that must go back to the exact same terminals. Take your time during removal and installation.

  1. Shut off electrical power to the furnace at the breaker and verify the power is off with a tester.
  2. Take clear photos of every wire connected to the board so you have an exact reference.
  3. Label each wire before loosening or disconnecting any terminals.
  4. Remove the old board from its mountings.
  5. Mount the replacement board securely in the furnace cabinet.
  6. Move wires one at a time to the matching spots on the replacement board.

Read your old part

  1. Locate the printed label or stamp on your current control board.
  2. Check that the label displays part number 24L8501.
  3. Verify that your furnace uses a 24 V control system.
  4. Confirm your heating equipment uses the SureLight Integrated Ignition system.
  5. Check that the board connects to a gas furnace.

When to call a pro

Board swaps on gas furnaces can need setup and testing. Hire a licensed HVAC technician for any step you are not sure you can do safely.

Questions

What voltage does the 24L8501 board run on?

The board operates on a 24 V control signal. Most home thermostats, contactor coils, and control boards use 24 V provided by a transformer.

Can I bypass a safety switch if the board shows a fault?

No, never bypass a flame sensor, pressure switch, limit switch, rollout switch, or float switch. These are safety devices designed to protect your home.

What ignition setup does this board use?

This part is specified for SureLight Integrated Ignition systems. The ignition type must match your furnace design.

What should I do before unplugging wires from the old board?

Always turn off power at the breaker and test for power first. Then take clear photos and label every wire before disconnecting anything.

Related part numbers

  • 1000-00032-00Control Board, FetcoSame part type
  • 00-748512Control Board, HobartSame part type
  • 60L21Blower Motor Reference, LennoxSame brand
  • 89M83Capacitor, LennoxSame brand
  • 108035Board Assembly Reference, FetcoSame part type
  • 300731Temperature Control Board, ClevelandSame part type
  • 300678Temperature Control Board, ClevelandSame part type

Browse: Control boards and defrost controls by part number

All part numbers · Part number replacements · Shop control boards · Repair guides

Brand names and part numbers identify the part and show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.