WNC2060 replacement pull-out AC disconnect

WNC2060 is a part number for an AC disconnect, the box near your outdoor unit that lets you cut power to it.

Our catalog lists the Siemens WN2060U as the replacement for WNC2060. It is a 60A non-fused pull-out AC disconnect switch in a NEMA 3R outdoor enclosure, rated for 240V.

Safety first. Turn off power at the breaker that feeds the disconnect and test for power before you touch any wire. The wires coming in stay live even with the block pulled. A disconnect is line voltage wiring. Have a licensed electrician or HVAC tech install it. Take a photo of every wire before you remove it, and move the wires one at a time to the same spots on the new box.

The part that replaces it

THIS PART IS LISTED AS REPLACING
  • WNC2060
FIT CHECK: MATCH THESE ON YOUR OLD PART
  1. Amps (FLA): 60 A. Compare with the label on your old part.

What a pull-out disconnect does

A disconnect lets you cut power at the outdoor unit so it is safe to work on. On a pull-out type, you pull the block out of the box to open the circuit.

Pulling the block does not make the box itself safe. The wires coming in stay live until the breaker that feeds the box is turned off.

Why the WN2060U is listed for WNC2060

The WN2060U lists WNC2060 among the numbers it replaces, and that listing is the fit data this page uses. Its specs read 60 A, 240 V, phase 1 and outdoor only.

What to match on your old box

  • Amps: the same rating as your old box. The WN2060U is listed at 60 A, and boxes are often 30 or 60 A.
  • Fused or not: the same as your old box. The WN2060U is listed as non-fused.
  • Volts: rated for 240 V, like the WN2060U.
  • Place: the WN2060U is listed for outdoor installation only.
  • Style: this one is a pull-out type in a NEMA 3R outdoor enclosure.

Signs a disconnect needs replacing

Look for rust, a melted pull-out block or burnt wires inside the box. Any of these is a reason to replace it. Because the power coming in is live even with the block pulled, leave this job to a licensed electrician or HVAC tech.

How to confirm it fits

  1. Find the part number on your old disconnect and confirm it reads WNC2060.
  2. Check the amps on the label. The WN2060U is listed at 60 A.
  3. Check whether your old box holds fuses. The WN2060U is listed as non-fused.
  4. Confirm the volts. The WN2060U is rated for 240v, phase 1.
  5. Check that the box goes in the same place as the old one. The WN2060U is listed for outdoor installation only.

When to call a pro

Hire a licensed electrician or HVAC tech for this swap. The power coming in is live even with the block pulled, and this is line voltage wiring.

Questions

What replaces WNC2060?

Our catalog lists the Siemens WN2060U, a 60A non-fused pull-out AC disconnect rated for 240V in a NEMA 3R outdoor enclosure, as the replacement for WNC2060. Check the amps, fused or not and the volts on your old box first.

Can the WN2060U be installed indoors?

Its specs list the installation as outdoor only. If your old box was indoors, ask a licensed electrician before you swap it.

Is the WN2060U fused?

No. It is listed as a non-fused 60 A disconnect. If your old box holds fuses, ask a licensed electrician before you swap it.

What voltage is the WN2060U rated for?

It is rated for 240 V, phase 1. Your old disconnect should be rated for 240 V too.

Is the power off when the block is pulled?

Not fully. The power coming in is live even with the block pulled. Turn off the breaker that feeds the box and test for power before you touch any wire.

Related guides