Fit Check on every partFree shipping over $4930-day returns
Help: contact us
HVAC FitterTHE PART THAT FITS
PART NUMBER LOOKUP

S1-02426090001 replacement fan blower control

S1-02426090001 is a part number for a fan blower control, a small control that works with the blower.

Our catalog lists the ICM Controls ICM253B, a fan blower control with an off delay on break and an adjustable delay of 12 to 390 seconds, as the replacement for S1-02426090001. It is also listed as replacing P284-2395 and ICM253.

Safety first. Turn off power at the breaker, then test for power before you touch any wire. Take a photo of every wire before you pull it, and move the wires one at a time to the same spots on the new control. Ask a licensed HVAC technician for help with any step you are not sure you can do safely.

The part that replaces it

THIS PART IS LISTED AS REPLACING
  • ICM253
  • P284-2395
  • S1-02426090001
FIT CHECK: MATCH THESE ON YOUR OLD PART
  1. Coil voltage: 18/30 VAC. Compare with the label on your old part.
  2. Amps (FLA): 1 A. Compare with the label on your old part.

What the listing says it is

The ICM253B is listed as a fan blower control with an off delay on break. Its delay is adjustable from 12 to 390 seconds.

It lists S1-02426090001, P284-2395 and ICM253 among the numbers it replaces, and that cross reference is the fit data on this page.

Numbers to compare with the old control

  • Coil voltage: 18/30 VAC.
  • Adjustable delay: 12 to 390 seconds.
  • Amps (FLA): 1 A. Inrush amps: 10. Holding current: 40 mA (minimum).
  • Frequency: 50 to 60 Hz.
  • Size: 2 inch by 3 inch.

What has to match

The coil volts must be the same. The contacts should act the same way, the amps should be the same or higher, and the delay should be set the same as on your old control. Read the label on the old control and check each number against the list above before you disconnect it.

How to confirm it fits

  1. Find the number on your old control and see whether it reads S1-02426090001, P284-2395 or ICM253.
  2. Check the coil voltage on the label. The ICM253B lists 18/30 VAC, and the coil volts must be the same.
  3. Check the delay. The ICM253B is adjustable from 12 to 390 seconds, and the delay should be the same as on your old control.
  4. Compare the amps and the frequency. The ICM253B lists 1 A and 50 to 60 Hz.
  5. Compare the size, 2 inch by 3 inch, so the new control sits where the old one did.

Questions

What replaces S1-02426090001?

Our catalog lists the ICM Controls ICM253B, a fan blower control with an off delay on break, as the replacement for S1-02426090001. It is also listed as replacing P284-2395 and ICM253.

How long can the delay be set?

The ICM253B lists an adjustable delay of 12 to 390 seconds.

What coil voltage does the ICM253B use?

It lists a coil voltage of 18/30 VAC. The coil volts must be the same as on your old control.

What does off delay on break mean?

The delay starts when the signal to the control turns off. The blower keeps running for the time you set, 12 to 390 seconds on the ICM253B, and then it stops.