PRMJ189 replacement 189-227 MFD start capacitor

PRMJ189 is the number of a start capacitor, a part that is used in hard start kits and is not a run capacitor.

Our catalog lists the Titan Pro TRMJ189, a round start capacitor rated 189-227 µF at 330 V, as the replacement for PRMJ189.

Safety first. Switch off the breaker and the outdoor disconnect, then test for power before you touch the capacitor or any wire. Discharge the capacitor with an insulated tool before anyone touches its terminals, because it can hold a charge with the power off. If you are not comfortable with the wiring, ask a licensed HVAC technician to do the swap.

The part that replaces it

THIS PART IS LISTED AS REPLACING
  • PRMJ189
FIT CHECK: MATCH THESE ON YOUR OLD PART
  1. µF reads 189-227. Must be the same. On a dual capacitor, the big number runs the compressor and the small one runs the fan.
  2. Volts read 330 or less. This part is rated 330v. Your old part must not be rated higher.
  3. It is round. Round and oval cans both work if they fit the bracket and the wires reach.

What to read on your old capacitor

Three things on the old label decide whether the TRMJ189 is the right match: the µF range, the volts and the shape. A start capacitor shows a range of µF, and this one reads 189-227.

Look for PRMJ189 printed on the old label. The TRMJ189 lists it among the numbers it replaces, and the range, the volts and the shape then decide the match.

Numbers on the TRMJ189 listing

The listing gives a capacitance of 189-227 µF (MFD) and a voltage rating of 330 V. It is a round can, 2-1/16 inch across and 4-3/8 inch high, and its type is start.

Volts and the range

Read the volts on the old capacitor. This part is rated 330 V, so your old part must not be rated higher than that.

The µF range is a hard match. A range that is only close is a different capacitor.

How to confirm it fits

  1. Look for PRMJ189 on the label of your old capacitor.
  2. Check that the µF range reads 189-227. It must be the same.
  3. Read the volts. The TRMJ189 is rated 330 V, and the old part must not be rated higher.
  4. Confirm that the old one is a start capacitor, not a run capacitor.
  5. Compare the round can, 2-1/16 inch across and 4-3/8 inch high, with the space where the old capacitor sits.

Questions

Which capacitor is listed to replace PRMJ189?

Our catalog lists the Titan Pro TRMJ189, a round start capacitor rated 189-227 µF at 330 V, as the replacement for PRMJ189.

What is a start capacitor used for?

It is used in hard start kits. It is not a run capacitor, so do not use it where a run capacitor belongs.

How do I read 189-227?

It is a range of µF (MFD), the way start capacitors are rated. Your old capacitor should show the same range.

Related guides

Brand names and part numbers are used only to show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.