Our catalog lists the Ditek DTK-120/240CMPLUS, a split phase surge protective device rated 120/240V, as the replacement for ICM517A-LITE.
The part that replaces it
Split Phase Surge Protective Device (120/240V) (Ditek DTK-120/240CMPLUS)
- ICM517A-LITE
- Voltage rating: 120/240V. Compare with the label on your old part.
- Phase: Split. Compare with the label on your old part.
What a surge protector does
A power spike that reaches the control board or the compressor can cause damage. A surge protective device sends the spike to ground before it gets there.
Most mount at the outdoor disconnect. That is why the mount and the size of the case matter when you pick a replacement.
Why this device is listed for ICM517A-LITE
The DTK-120/240CMPLUS lists ICM517A-LITE among the numbers it replaces. That listing is the fit data this page uses.
The specs list a voltage rating of 120/240V, split phase, a max surge current of 10kA and a NEMA-4X enclosure. They also list 40 A and an operating temperature of -31°F to 176°F.
What to match on your old unit
- Volts: match your unit. The DTK-120/240CMPLUS is rated 120/240V.
- Phase and volts: the DTK-120/240CMPLUS is listed as split phase at 120/240V. Check that the label on your old protector also reads 120/240V, and have the licensed electrician or HVAC tech who installs it confirm the phase.
- Mount: the device should fit near the disconnect where your old protector sits.
- Enclosure: the DTK-120/240CMPLUS lists a NEMA-4X enclosure. Compare the case with your old one.
Install notes
This is work on line voltage wiring. Shut the power off at the breaker first, confirm it is off, then move the wires from the old protector to the matching terminals on the new one. Mount it close to the disconnect, restore power and check that the unit starts normally.
How to confirm it fits
- Find the part number on your old protector and confirm it reads ICM517A-LITE.
- Check that your old protector is rated 120/240V, like the DTK-120/240CMPLUS (listed as split phase).
- Look at where the old protector is mounted. The new one should fit near the disconnect.
- Compare the case and the wire connections with the new device before you remove anything.
- Ask a licensed electrician or HVAC tech to confirm the match before you install it.
When to call a pro
This is line voltage wiring. If you are not trained, have a licensed electrician or HVAC tech install it.
Questions
What replaces ICM517A-LITE?
Our catalog lists the Ditek DTK-120/240CMPLUS, a split phase surge protective device rated 120/240V, as the replacement for ICM517A-LITE. Check the volts and the mount on your old protector first.
What does a surge protector do for an AC?
It sends power spikes to ground before they reach the control board and the compressor. Most mount at the outdoor disconnect.
What are the ratings of the DTK-120/240CMPLUS?
The specs list 120/240V, split phase, a max surge current of 10kA, a NEMA-4X enclosure and 40 A.
Who should install a surge protector?
It is line voltage wiring. If you are not trained, have a licensed electrician or HVAC tech install it.