HVAC Fitter lists the ROTOM FB-RFB241 blower assembly as a compatible replacement for Ruud 70-24157-03. Checking your existing motor ratings helps verify this part is the correct match for your furnace repair.
The part that replaces it
Shaded Pole C-frame Flue Exhaust Blower Assembly, Replaces Rheem Ruud 70-24157-03 (ROTOM FB-RFB241)
- 70-24157-03
- Horsepower: 1/20. Compare with the label on your old part.
- RPM: 3400 RPM. Compare with the label on your old part.
- Voltage rating: 115 V. Compare with the label on your old part.
What the Inducer Motor Does
An inducer motor vents the furnace during operation. It creates draft through the heat exchanger before the ignition sequence starts.
A safety pressure switch checks that the inducer is spinning and venting properly before the burners light. When an inducer begins to fail, you may hear a loud whine or grinding sound at startup. If the blower fails to pull enough draft, the pressure switch will never close, and the furnace will not light.
Why This Replacement Fits
The ROTOM FB-RFB241 is designed as a direct match for equipment requiring Ruud part number 70-24157-03. It matches the required electrical ratings and airflow performance of the original factory blower assembly.
This replacement features a 1/20 horsepower shaded pole motor that runs on standard 115 V power. It operates at 3400 RPM with 1 speed and draws 1.71 A. The open enclosure design and counterclockwise rotation allow it to seat and function properly in your Ruud heating unit.
Key Specifications to Match
Before choosing a replacement motor, always check the data tag on your current assembly. Specific electrical and physical ratings must match to ensure safe operation.
Never bypass a pressure switch, limit switch, or any safety control if your old assembly fails to start.
- HP and RPM: must be the same to maintain proper flue draft.
- Rotation: must match, CW or CCW, so combustion gases flow correctly.
- Outlet: must have the same shape and mounting holes for a secure exhaust fit.
Installation and Wiring Notes
Take a photo of every wire connection before removing the old blower. Move wires one at a time to the same spots on the new assembly to prevent miswiring.
Ensure all mounting surfaces are clean before securing the new assembly. A tight seal is critical because exhaust leaks can release dangerous fumes into your home. Hire a licensed HVAC technician for any step you are not sure you can do safely.
How to confirm it fits
- Horsepower: 1/20. Compare with the label on your old part.
- RPM: 3400 RPM. Compare with the label on your old part.
- Voltage rating: 115 V. Compare with the label on your old part.
- Check that your old part lists 1.71 A and CCW rotation.
- Confirm your blower outlet matches the shape and mounting holes of the ROTOM FB-RFB241.
Questions
What does an inducer motor do on a furnace?
It vents the furnace. The pressure switch checks it is running before the burners light.
What are common signs of a failing inducer motor?
Common signs include a loud whine or grinding noise at startup, or a furnace that will not light because the pressure switch never closes.
Can I bypass the pressure switch if the inducer motor will not turn on?
No. Never bypass a pressure switch, flame sensor, limit switch, rollout switch, or float switch because they are essential safety devices.
What should I do if I smell gas while checking the furnace?
If you smell gas, do not touch any switch. Leave the house and call your gas company from outside.
Brand names and part numbers are used only to show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.