For this part number, we list the ICM Controls ICM288 control board as a replacement. It is designed to match the electrical ratings and wiring needs of systems using the Rheem board.
The part that replaces it
ICM288 Furnace Control Board (ICM Controls ICM288)
- 62-24084-82
- Type: Control board. Compare with the label on your old part.
What the Furnace Control Board Does
The control board operates as the central brain of your furnace. Most home thermostats and control boards use a 24 V control signal from a transformer to call for heating or cooling.
When a cycle starts, the control board monitors essential safeties before running the motors. The pressure switch lets the furnace light only when the vent is clear and the inducer is running. Limit and rollout switches open when they sense too much heat and shut the burners off. Once safety switches close, the board powers the inducer, igniter, and blower motor.
Why the ICM288 Fits Rheem 62-24084-82
The ICM Controls ICM288 lists Rheem 62-24084-82 in its replaces list. It matches the electrical load requirements of the original control board.
The ICM288 has a line voltage rating of 98 to 132 VAC at 60Hz. It provides an igniter output of 5A at 120 VAC and an inducer rating of 4A at 120 VAC. For air circulation, it includes a heat blower rating of 5A, 1/2 HP, 250 VAC, and a cool blower rating of 10A, 2 HP, 240 VAC.
What to Match Before Installing
Always compare the new board directly to the old one before unhooking any wires. Check wiring and model match, because gas and control parts may need a pro.
Verify that the ignition type matches your furnace. Look over the terminal markings on the board to confirm that all required motor and safety connections are present.
Installation and Wiring Tips
Boards have many wires connected to them. Take clear photos and label each wire before you remove anything from your old control board.
Move wires one at a time to the same spots on the new board. Never bypass a flame sensor, pressure switch, limit switch, rollout switch, or float switch, as they are essential safety devices. If any step is unclear, stop and call a licensed technician.
How to confirm it fits
- Locate the part number on your existing board and confirm it reads Rheem 62-24084-82.
- Verify your system line voltage matches the board rating of 98 to 132 VAC at 60Hz.
- Confirm your igniter electrical requirement matches the 5A at 120 VAC output.
- Check that your inducer motor does not exceed the inducer rating of 4A at 120 VAC.
- Ensure your blower motor requirements fall within 5A, 1/2 HP, 250 VAC for heating and 10A, 2 HP, 240 VAC for cooling.
Questions
Which part replaces Rheem 62-24084-82?
The ICM Controls ICM288 control board is listed as a replacement for Rheem 62-24084-82.
What line voltage does the ICM288 control board require?
The ICM288 operates on a line voltage of 98 to 132 VAC at 60Hz.
Can I bypass a safety switch to test the new board?
No. Never bypass a flame sensor, pressure switch, limit switch, rollout switch, or float switch. They are safety devices.
Do I need to take pictures before removing the old board?
Yes. Take clear photos of every wire before removing anything, and transfer wires one at a time to the matching spots on the replacement board.
Related guides