We list part number 50M56X-843 as a replacement for 50M56U-843. It is a universal single-stage HSI integrated furnace control kit made by White Rodgers.
The part that replaces it
Universal Single Stage HSI Integrated Furnace Control Kit (White Rodgers 50M56X-843)
- 50M56U-843
- CNT05165
- Type: Control board. Compare with the label on your old part.
- Ignition type: Intermittent Hot Surface Pilot. Compare with the label on your old part.
What this control board does
A furnace control board directs each step of the heating sequence. Most home thermostats and control boards run on a 24 V control signal from a transformer.
The board checks safety controls before opening the gas valve and firing the burners. It coordinates the inducer motor, the igniter, and the indoor blower fan. If a safety switch opens, the board shuts down the heating cycle to keep the home safe.
Why 50M56X-843 replaces 50M56U-843
Part number 50M56X-843 is designed to replace part number 50M56U-843 directly. It also replaces part number CNT05165.
This board uses intermittent hot surface pilot ignition and supports 1 boiler stage. It is rated for an operating temperature range of -40° to 176°F. It uses a surface mount multipoise design with dimensions of 5-1/4 inches wide, 7 inches high, and 1-1/4 inches deep.
- Replaces part number 50M56U-843
- Replaces part number CNT05165
- Operating temperature rating of -40° to 176°F
- Dimensions measure 5-1/4 inches wide by 7 inches high by 1-1/4 inches deep
What to match on your old board
Before swapping parts, verify the details on your current equipment. You want to make sure the ignition style and physical size match what your system requires.
Take time to read the label on your existing board. Gas and control parts may need a professional, so review everything carefully before you begin.
- Check that your old part number matches 50M56U-843 or CNT05165.
- Confirm your system uses intermittent hot surface pilot ignition.
- Check the mounting space for a board measuring 5-1/4 inches wide, 7 inches high, and 1-1/4 inches deep.
- Confirm your system matches a 1 boiler stage setup.
Installation and wiring notes
Boards connect to many individual wires. Take clear photos and label each wire before you remove anything from your old control board.
Move wires one at a time to the same spots on the new board. Swapping control boards on gas furnaces can require setup and testing. Check wiring and model match before proceeding, and call a licensed tech if you need assistance.
How to confirm it fits
- Verify your old board lists part number 50M56U-843 or CNT05165.
- Confirm the part type is a control board.
- Check that your equipment uses intermittent hot surface pilot ignition.
- Verify your heating system is configured for 1 boiler stage.
- Measure your mounting area to ensure fit for 5-1/4 inches wide, 7 inches high, and 1-1/4 inches deep with surface mount multipoise support.
Questions
What other numbers does 50M56X-843 replace?
In addition to 50M56U-843, part number 50M56X-843 is listed to replace CNT05165.
What ignition type does this replacement control board use?
It uses intermittent hot surface pilot ignition.
What are the dimensions of this board?
The board measures 5-1/4 inches wide, 7 inches high, and 1-1/4 inches deep.
What should I do before disconnecting any wires?
Turn off power at the breaker, test for power, and take clear photos to label every wire before disconnecting anything.