50A65-120 replacement furnace control board

50A65-120 is a part number for a furnace control board, the circuit board that runs the start-up steps of your furnace.

Our catalog lists the White Rodgers 50A65-843, a universal nitride ignition furnace control, as the replacement for 50A65-120. It is also listed as replacing 50A65-288 and 50A65-143.

Safety first. Turn off power to the furnace at its switch and at the breaker, then test for power before you touch the board. Take clear photos of every wire and label each one before you remove anything. If you smell gas, do not touch any switch. Leave the house and call your gas company from outside.

The part that replaces it

THIS PART IS LISTED AS REPLACING
  • 50A65-120
  • 50A65-143
  • 50A65-288
FIT CHECK: MATCH THESE ON YOUR OLD PART
  1. Type: Control board. Compare with the label on your old part.
  2. Ignition type: Intermittent Hot Surface Pilot. Compare with the label on your old part.

What a furnace control board does

The control board is the brain of the furnace. When the thermostat calls for heat, it runs the start-up steps and decides when the igniter heats and when the burners light. If the board fails, the furnace may do nothing or may stop partway through a start.

Why this board is listed for 50A65-120

The 50A65-843 lists 50A65-120, 50A65-288 and 50A65-143 among the numbers it replaces. That listing is the fit data this page uses. Each board lists the part numbers it replaces, so find the number on your old board and look for it here.

What to match on your old board

These are the points to check. Ask a licensed technician if any of them is unclear.

  • Part number: your old board should read 50A65-120, 50A65-288 or 50A65-143.
  • Ignition type: the 50A65-843 is listed for intermittent hot surface pilot ignition, so it should be the same as your furnace.
  • Wiring: photograph every wire first, and move the wires to the same spots on the new board.

Install notes

Check wiring and model match before you install the board. Mount it in the same place, move the wires one at a time and restore power. Watch one full start to see that the igniter heats and the burners light.

How to confirm it fits

  1. Find the part number on your old board and confirm it reads 50A65-120, 50A65-288 or 50A65-143.
  2. Check the ignition type. The 50A65-843 is listed for intermittent hot surface pilot ignition.
  3. Take photos of the plugs and every wire on your old board before you remove anything.
  4. Compare the plugs and the wire connections with the new board before you connect it.
  5. Not sure about the wiring or the model match? Ask a licensed HVAC technician to confirm.

When to call a pro

Board swaps on gas furnaces can need setup and testing. If you are not sure, call a licensed tech.

Questions

What replaces 50A65-120?

Our catalog lists the White Rodgers 50A65-843, a universal nitride ignition furnace control, as the replacement for 50A65-120. It is also listed as replacing 50A65-288 and 50A65-143.

What ignition type does the 50A65-843 list?

It lists intermittent hot surface pilot ignition. Check that your furnace uses the same ignition type before you swap the board.

Can I replace a furnace control board myself?

Board swaps on gas furnaces can need setup and testing. If you are not sure, call a licensed tech. Turn off power first and photograph every wire.

What should I do if I smell gas?

Do not touch any switch. Leave the house and call your gas company from outside.