This part is out of stock right now, so it cannot be added to the cart.
If your equipment fails to heat, fails to cool, or does not respond to changes at the control, the thermostat may need attention. This guide helps you identify the part, check its measurements, and review safe handling steps.
Specifications
- Part number: 369801
- Brand: Lincoln
- Part type: Thermostat
- Height: 3.35 in / 8.51 cm
- Length: 3.5 in / 8.89 cm
- Width: 5.85 in / 14.86 cm
- 461752
- System: gas, electric or heat pump, as listed
- Stages: heat and cool stages your system uses
- C wire: needed by some models, check yours
From the maker's and parts sellers' listings for this number. Compare them with the label on your old part.
What this thermostat does
A thermostat senses the temperature in your space and compares it to your setpoint. When heating or cooling is needed, it closes an internal circuit to call for conditioned air.
Most central HVAC equipment relies on a 24 V control signal from a transformer. Baseboard heating units run on line voltage instead. Because these systems operate on completely different electrical setups, confirming your setup is critical before servicing the controls.
Measurements and physical specs
Physical dimensions help you verify that the housing fits your existing mounting space or wall bracket. Check your old unit against these measurements.
- Height: 3.35 in / 8.51 cm
- Length: 3.5 in / 8.89 cm
- Width: 5.85 in / 14.86 cm
Matching the correct replacement part
When matching a thermostat, always confirm your heating and cooling system type, such as gas, electric, or heat pump. You also need to verify the number of heat and cool stages your equipment uses.
Some thermostats require a dedicated common wire, known as a C wire, to supply continuous power. Inspect your current wiring bundle to see if your setup provides one.
Part number 369801 replaces part number 461752. If your old unit is labeled with 461752 or 369801, this part matches that reference number.
How to replace a thermostat safely
A bad thermostat may fail to send a call for heat or cool, or it may lose power entirely. Once you confirm power is off, you can remove the old faceplate and disconnect the wiring.
- Shut off power to the furnace or air handler at the breaker or power switch.
- Remove the front cover of the old thermostat from the wall.
- Take a photo of every wire before removing a part to record which wire connects to which letter.
- Disconnect the wires, keeping them from slipping back inside the wall opening.
- Move wires one at a time to the same spots on the replacement unit.
- Restore power at the breaker and test the equipment for proper operation.
Read your old part
- Shut off power and pull the existing thermostat off its mounting base.
- Look at the label on the back or inside the housing for the part number.
- Confirm the label shows part number 369801 or replacement number 461752.
- Measure your existing space to ensure the height of 3.35 in / 8.51 cm, length of 3.5 in / 8.89 cm, and width of 5.85 in / 14.86 cm will fit.
- Verify whether your setup is gas, electric, or heat pump, and check if a C wire is present.
When to call a pro
Hire a licensed HVAC technician for any step you are not sure you can do safely. If your system involves line voltage wiring, unusual wire configurations, or you smell gas, stop immediately and contact a professional.
Questions
What part numbers does the Lincoln 369801 replace?
The Lincoln 369801 replaces part number 461752. Always check the label on your old part to confirm one of these numbers matches.
What are the dimensions of part 369801?
This part measures 3.35 in / 8.51 cm high, 3.5 in / 8.89 cm long, and 5.85 in / 14.86 cm wide. You can compare these dimensions to your existing installation space.
Do I need to take a photo of the wiring before removing my old thermostat?
Yes. Taking a photo of every wire before removing the old part ensures you know which wire connects to which letter terminal. You can then move wires one at a time to the matching spots.
Is part 369801 a line voltage or low voltage thermostat?
Most central systems use 24 V thermostats, while baseboard heaters use line voltage. Check your equipment specifications and existing wiring before replacing any control.
Related part numbers
- 370736Thermostat Export Fusion, LincolnSame brand and type
- 300701Hi-Limit Thermostat, ClevelandSame part type
- 369178Contactor Reference, LincolnSame brand
- 46910700Thermostat Specs and Replacement Guide, APWSame part type
- 18782Thermostat, GaylordSame part type
- 369131-CLEThermocouple Probe Assembly, LincolnSame brand
- C7189U1005Thermostat Part, HoneywellSame part type
- 18781Thermostat, GaylordSame part type
Browse: Thermostats by part number
All part numbers · Part number replacements · Shop thermostats · Repair guides
Brand names and part numbers identify the part and show fit. HVAC Fitter is not affiliated with, authorized by, or endorsed by any equipment maker. If you are not sure a repair is safe for you, call a licensed HVAC technician.